-40%

Lipid Test Meter Cholesterol Meter Analyzer Triglycerides Test Meter Kit + Strip

$ 100.38

Availability: 15 in stock
  • Return shipping will be paid by: Buyer
  • Restocking Fee: No
  • Sample Type: Blood
  • Modified Item: No
  • Custom Bundle: No
  • Model: Lipid Test Meter
  • MPN: Does Not Apply
  • Item must be returned within: 30 Days
  • Condition: New
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money Back
  • Display Type: LCD
  • Manufacturer Warranty: 1 year
  • Brand: ZSK lipid test meter
  • Expiration Date: Within the validity period
  • Type: Test Kit
  • Country/Region of Manufacture: China

    Description

    Lipid Analyzer Test Meter Cholesterol Meter Analyzer Monitor HDL LDL Triglycerides Test Meter Kit
    Test Items : Total cholesterol , triglycerides , high density lipoprotein , low density lipoprotein , CHOL/HDL ;
    Measuring principle : Dry chemical analyzer ;
    Operating temperature:Lipid profile : 18-35℃ ;
    Operating humidity : ≤80% ;
    Screen type:LCD Display ;
    Sample volume:40ul ,Whole peripheral blood or vein blood ;
    Test Range:TC:2.59mmol/L--10.35mmol/L ;
    HDL:0.39mmol/L--2.59mmol/L ;
    TG:0.51mmol/L--5.56mmol/L ;
    Record store : 500 groups ;
    Test Time:2 Minutes ;
    Power saving mode:Automatic shutdown without any operation instrument for 2 minutes .
    Blood collection mode: siphon .
    Package including :
    1pc lipid test meter ;
    5pcs lipid test strips ;
    5pcs lancets
    .
    5pcs blood collection tubes .
    (Note :the batteries are not included in the package)
    Operating Steps:
    1. Press the power button to start the machine. After starting the machine, long press the power button to enter the main page of the system and select the power button to enter the system setting interface .
    2. Insert the code card from the side of the instrument. Note: the flat side of the code card is close to the upper end of the card .
    3. Make sure the codes on the instrument, the test card box and the single package of the test card are consistent .
    4. Use disposable blood sampler to collect blood .
    Note: after disinfecting with alcohol , take blood after the alcohol evaporates .
    5. Blood collection .
    Note: the blood collection vessel is tilted downward to draw blood to the scale line . When the blood volume is insufficient, the blood collection tube is laid flat and the blood is collected after the blood sample is sufficient. During the blood collection , bubbles are avoided as much as possible .
    6. Insert test card under the instrument .
    7. Add a blood sample .
    a. when the symbol of blood drops flashes, add blood sample.Squeeze the upper end of the blood vessel with your finger so that the blood sample comes out of the vessel and is added at one time .
    b. Blood vessels should not touch the test card .
    8,Two minutes or so display the results.Reference values :  TC < 5.17mmol/L , HDL > 1.04mmol/L ,TG < 1.70mmol/L .